Example 9-2 Safety in Chemical Plants with Exothermic Reactions |POLVER05_0 d(T)/d(t) = if (t<45) then (0) else ((Qg-Qr)/NCp) # d(X)/d(t) = (-ra)*V/Nao # NCp = 2504 # V = 3.265+1.854 # Nao = 9.0448 # UA = 35.83 # dH = -590000 # Nbo = 33 # k = .00017*exp(11273/(1.987)*(1/461-1/T)) # Qr = UA*(T-298) # Theata = Nbo/Nao # ra = -k*Nao^2*(1-X)*(Theata-2*X)/V^2 # rate = -ra # Qg = ra*V*(dH) # t(0)=55 T(0)=467.992 X(0)=0.0423866 t(f)=121